Baseboard heat not working upstairs. Sorry for the long post.

Baseboard heat not working upstairs. At 44% efficient at -22f, with a COP of 3.

Baseboard heat not working upstairs We had to go to the high point of the piping, take 2 pipe wrenches and loosen up the union there to bleed the air out so it would work. - A little background. I can get the water moving upstairs by releasing some water from the blow-off valve for a second or two, which, if I had to guess, creates a siphon. Dec 23, 2024 · Good morning, The heat is only working on a few of the baseboard heaters and a bunch of the rooms they are not. You have to shortlist the typical problems based on your situation. The heat upstairs still doesn't work. In the other bedroom the pipe is cold and obviously not radiating heat either. I opened the pipe on a 1st floor run to swap a panel radiator in the kitchen for one of the slant fins. 2. Here are the 5 reasons why the baseboard not working in one room and their easy solutions. That sounds like hot water baseboard heat to me and if the pipes run upstairs inside of exterior walls then you have to worry about them possibly freezing. Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. so how do I use the bleed copper drops to bleed air up in attic. Maintaining a free space of several inches in front of the heater will rectify this problem. They can't do anything because they are not plumbers. Q: Can I reset an overheated heater myself? I wake up and go upstairs to take a shower. However, like most things, they have their disadvantages too. Thermostat to this zone is bad or not calling. Even the basement can get too hot when you’re trying to heat the upstairs. So it's going to be -14 this week, and I have no heat in 1/4 of the house. The thermostat seems to be working. When I turn up the thermostat upstairs the boiler doesn't turn on, I even bypassed the thermostat and spliced the 2 wires together. Ensure a cozy winter with Nov 17, 2012 · The boiler is running fine. That’s double the cost. The pressure guage reads 15psi yet i do not have heat in the house. Bad, stuck or intermittent zone valve. Apr 29, 2003 · I just topped off the furnace and turned the heat up 10 degrees. Ok, probably no need for a call. All zone valves operational. Hello there, I'm attempting to get the upstairs top floor baseboard heaters working. There might be a problem with the aquastat but that seems unlikely since the burner fires with the upstairs thermostat. None of the radiators upstairs have on-radiator bleeders. So here are some tips on maintaining the baseboard heater. If I cut a section of the copper pipe between the baseboard heaters, install a "T" and then solder a 2 foot section of pipe as a riser to elevate a valve above the highest point in the system, might bleeding the system that way, allow water to rise? Well the good news is that your boiler is working and we just have a zone issue. Jan 24, 2014 · Boilers - Home Heating Steam and Hot Water Systems - 2 zones. No heat in upstairs loop. Thermostat is on, it’s been reset and batteries have been replaced. Jan 1, 2018 · I have a Burnham hydronics series 2 boiler and it’s only heating the finished basement zone and not the upstairs zone. The upstairs thermostat seems to be working i. I have an oil furnace that is running normally and I do have hot water in the house. zone 1 works, the hot water system works-all 3 circ pumps turn on. My son actually was able to get some heat going upstairs by constantly bleeding the return. 2 zones are in-floor heat, 1 for the basement and 1 for the garage. The heat loss program I use has been very reliable, so I'm thinking it's a house issue. The closer the rads to the boiler the lower the vent setting. I am not sure what else I can do to get this resolved. Oil fired boiler. Troubleshooting The heat is working in every room except the living room and my wife’s office. Does it sound like there's still a air pocket or something somewhere? You can not have baseboard copper fin on the same thermostat or zone with cast iron. Resetting your baseboard heater can help resolve issues such as lack of heat or uneven heating. We tried putting the heat on and it didn’t work. Brand new Biasi. We have a water heater/gas furnace and baseboard heat. Explanation of my sisters hydronic hot water baseboard heating and possible reasons for failure to heat specific zones or hot water heater Feb 23, 2020 · Yesterday, one of the bedroom radiators stopped getting hot. Sep 25, 2024 · Many baseboard heater issues stem from a faulty heating element or thermostat. I am confused and i need help. Baseboard heaters cost a lot less than a second Sep 12, 2024 · This not only saves you time, but also ensures the baseboard heater work is done safely, as HVAC systems have electrical components that can be tricky (and sometimes hazardous) to handle. Knowing the problems can help you solve different baseboard issues. There are a couple of ways to balance the system. You could have an air lock or the circulator may not be coming on when the first floor calls for heat. The upstairs zone is heating but not reaching the desired temp. I like the combination and flexibility. But sure enough, a few days later, the heat was not flowing like it should. Thermostats work. But check the boiler, your upstairs zone is getting water, but downstairs is not, that tells me that you have either a zone valve, or a zone pump, not working. Here are some common reasons why an electric baseboard heater may not be working: Power Supply Issues Ensure that the heater is receiving power. The basement thermostat works great, the upstairs one not so much. Hi I live in a electric baseboard heating,why does my thermostat when we set it at low setting the heat stay hot and not shut off this happens on all 4 thermostat s do you have an answer. First time home owner here. I shutoff boiler and all return valves above pumps and bleed one at a time with a hose to a bucket for a long time . We do not have gas due to condo rules and have all electric. A few plumbers have come by and suggested changing the furnace When we moved into our house we had baseboard heat and regular AC. I’m also not hearing any sounds like air in the pipes. Any help would be greatly appreciated! Dec 13, 2010 · The first floor is baseboard heating, and the second floor uses radiators. Always check that the thermostat is set to “heat” and the temperature is set above the room temperature. Dec 15, 2017 · When you say heat doesn't reach 2nd floor do you mean it's heating up slower or not heating at all. Maintains house temp easily and only comes in about 3-5 times an hour for about 6 min every-time. Oil-filled or water baseboard heaters may have trapped air, blocked valves, failing pumps, or faulty relays. Plus your pipes will usually give you plenty of warning by groaning, squealing, and gurgling before your system becomes completely bound up. Nov 11, 2020 · It can heat up the main floor in about 2 minutes, but no heat upstairs by the time the furnace shuts off. Apr 17, 2010 · 2. Oct 30, 2019 · Hi, I just bought a two family house, two story house with basement that has one very old American Standard boiler from the 1950s. e. Read: How to clean old baseboard heaters 7. We are getting heat upstairs but downstairs nothing. Nov 29, 2013 · We have one thermostat on the first floor and the heat works fine in the basement and on the first floor. They’re not very expensive, and they’re easy to install. Looking out for the signs of a broken baseboard heater saves you the trouble of dealing with more damage. When it calls for heat, the motor on the pump turns. However, it can be quite unsettling when you go to turn off your baseboard heater and nothing happens. The front of house and upstairs has cast iron radiators which work fine. They have many advantages over other types of home heating. This resolution didn't work either. patreon. Zone Customer: I have a boiler with baseboard heat. First, make sure your radiators are clean. May 14, 2024 · Resetting Your Baseboard Heater. I am not getting heat where I am supposed to have heat. close the ball valve, hook a hose on the hose bibb/drain, open the drain, put the feeder on bypass then let the water run until no air came out of the hose then for several minutes more. No wall furnace, no baseboard heaters, nothing. The first floor works very well, no problems, but the baseboard units upstairs are not working. CT 2. Gas baseboard heaters operate by burning natural gas to produce heat. It has been in the 40s outside since closing the valves and I currently have three windows with a single layer (storms are out) so it's not exactly retaining heat. Our baseboard heaters are pretty well placed but we could easily rip out half of them if we needed to. I therefore remove the t-sta The zone you’re having problem with I would hook a hose up to that valve with the hose barb on it right there shut the gas off so you know that the boiler burners aren’t gonna come on drain that into a bucket and see if you get air coming out allow the pump and everything to run don’t shut off the power of the boiler allow it to fill back up and see if you’re getting here OK out of Mar 10, 2020 · Gas and electric baseboard heaters offer distinct advantages and challenges, and understanding these can help you make an informed decision or manage the system you currently have in place. Now I am stuck. However, if they’re not working correctly, they can restrict the flow of hot water. Oct 27, 2018 · So we have a 2 floor townhouse. Oct 23, 2005 · The heating system is 40 years old, hot water baseboard, the "boiler" is called "Instant Hot"? but there's no holding tank. Plus, baseboard professionals bring the necessary tools and replacement materials with them, so they can get the job done smoothly and efficiently. Once I hear the heat kick on I remove the two zone control valves for zones upstairs. Space heaters do roughly the same thing but cheaper and lesser. Customer: I have a boiler with baseboard heat. None of the baseboard loops are hot, and the pipe was hot before the circulator pump but not. On the positive side, the house seems to be heating a lot faster, quieter and evenlythe pressure is still at 18. Sorry for the long post. Up stairs, we’ve got nothing. Oct 28, 2012 · Boilers - Home Heating Steam and Hot Water Systems - no heat upstairs baseboards - Looking for advice on how to troubleshoot a heat issue. Cold water comes out of another baseboard. is flashing. Do you know what zone control you have? Nov 14, 2024 · If your hot water baseboard heat isn’t working, follow these steps to identify and resolve the issue. Joined Sep 11, 2011 · 1,662 Posts Dec 27, 2017 · But if it's not heating the house even though the burner is on continuously, the issue is most likely going to be either the programmed output temperature is not high enough, or you don't have enough radiation to emit enough heat at the maximum temperature of 180F. The pipes are not insulated. I just realized recently that my second zone upstairs is not heating up, but working on the first floor (zone 1). Dec 12, 2021 · 8. In which area you live and ambient temperatures you usually experience. Not cost effective or smart as the temperature on the dining room will determine if the heat will even turn on or not in the other rooms so I would essentially need to have it full on always. D. bled the radiators, could not discern any air problems. Jul 13, 2024 · Note if fins are damaged beyond repair, you’ll need to replace the whole unit. The movement of cold air through the bottom of the heater and warm air through the top creates a natural convection current that keeps air circulating naturally from Feb 25, 2013 · I checked the system again. If it sounds hollow than the membrane should be good and the tank working. I've made a casual survey of the upstairs baseboards and have not yet found one. It's a small cape, with cast iron radiators throughout the first floor, and one steel radiator (steel fins, that is) under a metal cover under each window (at the end of the room) in each of the two rooms on the second floor. The top floor is fine but living room downstairs seems cold at certain points and I keep the temp at 60-64 as anything higher is increasing the electric bill a lot. How It Works. Not an expert but from what I know, electric baseboard heaters don’t have pipes going to them. replace your system with effectively two systems, one for upstairs and one for the basement (most likely VERY expensive). When I do that I can hear water rushing through the pipes and the baseboard heaters upstairs start to heat up. On the main floor, no problem (direct vent gas wall furnace). The basement is insulated, 1st floor joists that is. We have a gas furnace with three zones which feed both floors and the basement. 5x more efficient than a baseboard heater Mar 27, 2001 · Thanks all for your replies and advice. My pressure on boiler was below one but I’ve Dec 26, 2024 · An appliance like a hot water baseboard heater requires regular maintenance. Nov 5, 2007 · At the same time I hooked a hose up to the drain for the section that isnt working and forced water through the entire system allowing it to drain out the bottom. Baseboard heaters are no exception – having a baseboard heater not working in one room or in your entire home can be a huge problem both from a financial and a practical point of view. I assume either a blockage is somewhere in the upstairs zone or air needs to be purged from the zone. Regular Cleaning. When your baseboard heater is not functioning properly, one of the troubleshooting steps you can take is to reset it. pics of baseboard heaters and boiler . The forecast looks warm: If I switch off the heat at the thermostat, can I then safely turn off the main water to the house? What would happen if I left the thermostat set very, very low with the main water off? Feb 21, 2016 · Close the circuit breaker: the heaters stay at room temperature. 1. There could be a short in the thermostat or its wiring, but the thermostat probably has nothing to do with this. Post results back here. upstairs the pipes are cold. Jul 19, 2022 · Your baseboard heater not working in one room can be caused by a frozen line, airlocks, broken circulator pump, dirt buildup due to lack of cleaning, lack of airflow, tripped circuit breaker, lack of electrical supply, thermostat not working, and heating element not working. The upstairs baseboards are very warm but no heat to the downstairs. Both my main floor and basement have separate thermostats. Lower floor is also good (baseboard heaters in two rooms). When i try to bleed the baseboard, hot water comes out of the bleeder, but the baseboard remains cold. Each zone has a honeywell zone valve. I am not an expert in baseboard heat, so my terms may be inappropriate or wrong. Sorry if my explanation is hard to understand. My water temperature was 180F, I just increased it to 190F (to try if that makes a difference) . If your baseboard heater won’t turn off, it is likely due to the thermostat. Baseboard Heater Circuit Breaker Trips Dec 1, 2024 · Understanding Hot Water Baseboard Heating. In fact, it feels like it is circulating cold water. These help transfer heat. Sep 28, 2008 · Here's the current problem: The system is 4 zones - 3 for baseboard heat, one for a boiler mate. Today we have no heat upstairs. I'm not sure when it failed, but we noticed it when we turned in for the night. They are very quiet, unlike furnace heating, and they have excellent room temperature control. Still No heat upstairs but. And I hear the pipes moving water and vibrating behind the baseboards Oct 5, 2010 · If after having the thermostat up for 10-15 minutes. The Taco zone box shows there’s a call for heat. Jan 6, 2014 · I need help resolving an issue with baseboard heat. The furnace is in the basement, and since it is heating zone 1, can it be the circulator? Dec 28, 2017 · One zone of 4 on my boiler is not putting out heat. Regular baseboard heater maintenance helps prevent common issues. I very confused about what is required. How Does Heating Baseboard Work? Hot water heating baseboard is warmed by hot water circulating through either finned copper tubing or through cast iron baseboard sections. I tried switching the thermostats What I have going on, is the upstairs return pipe never gets anything more than barely warm, while the downstairs is too hot to hold. I can set the thermostat above the current temperature, and my heater will turn on, but it won't do much when the outside temperature is mildly cold or lower. Mar 12, 2009 · heating solution sound like air to me. When I went to fire up the boiler this year, everything seemed to be working fine, but the baseboards aren't heating up. Turned the system on again and set temp to 80 to test, I can hear a click at the boiler and a low buzz afterwards (which happened before too), however I am not hearing any water circulating to either upstairs or downstairs baseboard and both baseboards are cold to touch even when both thermos are set to 80. Turn on the heat using the downstairs thermostat. Dec 1, 2024 · Rear of house getting warm front not as warm and the one room has a add on baseboard heater tats not as warm. Verify that the expansion tank is in working order. The problem is quite simple. Dec 26, 2023 · An electric baseboard heater not getting warm may have thermostat issues, obstructed airflow, and electrical problems such as wiring, voltage, and breaker. Jan 6, 2015 · Unless there is a valve in the line that's shut off, you probably either have an air blockage (which either means you need to find a bleeder you haven't yet, possibly hidden under the baseboard cover, or you need to cut the pipe and add one) or you have a frozen pipe (surprisingly common with the way some baseboard systems are installed On bitterly cold days, this can happen with baseboard heat. I have gone through and replaced all the autovents upstairs and went around purging every baseboard until only water comes out, but still not heat. Faulty Thermostat. It belongs to my 80 year old mother and I am a NY city boy with little familiarity with the care and feeding of a hot water baseboard heating system and oil fired Jan 7, 2010 · So, I bled it again tonight and waited longer for everything to drain out. Underside insulation on home has fallen down completely, pipes for heating are copper and they run in the crawlspace. Always try to apply lubricant on the valves that are present inside the baseboard heater. Video attached if needed. If it's a zone valve system the valve may be stuck closed and you can manually open said zone valve with the little lever that's on the valve. Worked on purging the air but the only radiators in the house that have accessible purge valves are the newer ones installed in the additions (back office and kitchen) and they are clear. Options I see are - 1. Q: How often should I replace my electric baseboard heater? A: Electric baseboard heaters typically last 10-15 years. You should see a bunch of metal fins in your baseboards. Sep 23, 2021 · These solutions vary in cost and also work differently from one another. It loses efficiency as it probably needs to spend time heating the outside unit. It had been working well (sometimes too well) for years previously. in one of the bedrooms upstairs the pipe in the baseboard is hot, but it doesn't seem to be radiating any heat. One baseboard unit on 2nd floor doesn't heat up. Dec 22, 2023 · I’ve recently moved into a new build and my upstairs radiators are not working Ive got two thermostats one for upstairs and one for downstairs. Sep 30, 2021 · That way, you have models that are made to work in tandem. The upper zone is not turning on. Jun 21, 2021 · Baseboard Heat Not Working In One Room [5 Reasons & Solutions] It’s important to know why the baseboard heater not working upstairs or downstairs. This system relies on key components to function properly. If I am doing the 203 loan and can make these changes (the baseboard heaters upstairs) after we close why is she holding my loan back. Nov 29, 2024 · Common Causes of Water Baseboard Heater Not Working. Jan 24, 2021 · SECOND FLOOR HEATING ZONE NOT WORKINGmerch = https://teespring. I apologize if I am writing about the same issue, but I haven't found specifics to help my situation. Given that everything seems to work as expected, why my second floor baseboards are cold ? Nov 12, 2017 · Once you are convinced that none of the heaters and /or pipes contain trapped air you should verify the water pressure in the system. The back of the house has baseboard rads that loops from the main burner pipe. Gas company came out, gave boiler, valves etc. I'll try to be as accurate as possible. The downstairs radiators are whistling like crazy, the upstairs radiators got hotter but they aren't whistling like the downstairs ones. If your heater is not working in one specific room, the first thing to do is to check and ensure that no furniture or other items are blocking off the vents. Watch out : as shown in our photo: this older baseboard heat installation is missing its end-cover That won't have much effect on heat transfer but it might mean that a barefoot walker could cut her toes on the Mar 6, 2020 · It’s always annoying to see your home’s heating system malfunction, especially when it happens in the middle of a cold winter. I would locate the zone valve for that circuit and see if it has a manual lever on it to open the zone. Apr 28, 2020 · The upstairs heat does not seem to circulate beyond the master bedroom - the on-suite bathroom radiators are cold and the other upstairs bedrooms and bathroom radiators remain cold. 2nd floor zone heat not working - Hello, We have a 2 zone heating system. everything seemed to check out. The heat registers are still hot (less so on the farthest loop, which has always been the case) and the temperature is still sitting at 69 degrees. You might still come out ahead relying only on the mini split in extreme cold since the baseboard heat is not efficient at all. Yesterday we had a baseboard pipe leak in down stairs zone. I would love hear some advise or thoughts. Nov 12, 2010 · Boilers - Home Heating Steam and Hot Water Systems - Help please. Mar 9, 2019 · Full Article:https://www. Jump to Latest 21 - 27 of 27 Posts. i check all the other baseboards upstairs and they are all heating up. The 3rd zone, and the one that is causing issues, is upstairs and controls hydronic baseboard heaters. Check all of your baseboard to make sure it is getting hot. Dec 15, 2013 · Additionally, look for bleeder valves on your baseboard heaters as suggested above. additional pics of boiler . It will just keep running and won't make much heat. Air in your heating system can block hot water from circulating properly. aconcordcarpenter. Zoned Heating Fixing ductwork or ripping open walls to add insulation are costly and invasive propositions. Sediment Buildup in Water Heaters Affecting Water Flow Jan 27, 2015 · How Hot Water Baseboard Heaters Work. Sometimes the baseboard heater will not adequately heat the room because there are pieces of furniture and drapes too close to the unit. Several factors could prevent your water baseboard heater from functioning. It really simplified the look of my first floor, they are wall hung and sit about 4 inches from the floor and look quite nice. This rapidly moves the water upstairs, and once I do this, it works fine for two or three days, but then gets stopped up Apr 27, 2010 · Hydronic heating systems are highly energy efficient and are based on either baseboard or convection units. Ok why do we have to turn the thermostat on or off to get heat the stat should work by shutting off when reaching temp. I am guessing I might have introduced air by turning the water main off. We will also discuss when it may be necessary to seek the assistance of a professional heating technician. The other two zones work as expected, and the other two rooms in the affected zone work very well too. Second zone is a basement. bleeding baseboard heater Hey all I have a question. Keep reading as we cover the common reasons for baseboard heater failure with their solutions and other troubleshooting methods. Hot water baseboard heating provides effective warmth by circulating hot water through pipes installed along walls. Start at lowest level then work up. These were bare copper pipes). Getting hot water heat upstairs My home (built in 1948) uses a one-pipe closed hot water heating system. Still the same case -- no heat to the 2nd floor baseboard heating. Baseboard heat/ boiler/ propane. The issue seems to be that my Ecobee 3 thermostats (I have 2) is asking the bottom zone for heat due to what I have it set at and since the zone isn’t turned on it’s bypassing that zone and pushing that into the main floor baseboard heaters. Just to be sure it wasn’t the heating assembly, I checked the motor and mechanisms. Feb 5, 2013 · I suggest using gloves or see if you can touch it with a screw driver. I have the thermostat set as low as 50, but still it gets up to 70 degrees up there. One baseboard zone will not get to temperature. We were told we have a frozen pipe in a wall but it's been several days with the heat on everywhere else and non-freezing temps out so I'm wondering if there is another issue with a valve or otherwise. The AC comes on just fine but not the heat. I laid out the procedure in a previous post. Though you say you tried this already. Q: What are the signs of damaged wiring? A: Look for loose connections, frayed wires, or burning smells. The other day I realized that upstairs radiators are only a little warm and not as warm as the first floor. My friend has gotten the heat going throughout the entire house (built in early 1800's) except for one room upstairs that runs off a third line. Understanding these common causes helps in diagnosing and resolving the issue effectively. The downstairs baseboards are not heating at all. The only way to balance steam is with the vents to make sure steam gets to rads at same time. I have no heating upstairs, the basement and the main floor heat fine. Discover effective troubleshooting tips, from bleeding radiators to flushing the system, and learn when to call a professional for persistent problems. Not only does it prolong the heater’s lifespan and improve efficiency, but it also helps identify potential threats earlier. However the second floor baseboards are ice cold and I was able to trace the issue all the way back to the furnace. All three are not working, whereas they were before. . Turned off all thermostats and then turned each one up individually but i suspect temperature wasnt low enough for call for heat hence burner to fire up. I have a problem with 1 of my baseboards not heating up with a hot water system. Baseboard heaters collect dust and debris all the time. None of the baseboards on one side of the house in that zone work, while the baseboards on the other three walls does work. Di Mar 27, 2021 · The hot water baseboard heat in the apartments where I used to work as a maintenance tech were constantly acting in the manner you describe. Mar 9, 2014 · I have three heating zones (forced hot water in baseboards) in my house. Dec 11, 2017 · Boilers - Home Heating Steam and Hot Water Systems - Half of baseboard system getting hot, other half, not. The baseboard heaters upstairs don't have any bleeder valves installed on them whatsoever, The 4th picture I uploaded are the pipes that lead to the top floor, they are hot, however the pipes upstairs are cold. If the circulator shuts off when the thermostat shuts off but the radiators stay hot, most likely you are getting gravity flow because the flow check or zone valve was opened manually and not returned to its normal automatic position, or is defective and not closing as it should Dec 2, 2013 · All the voltages and resistances seem to be inorder. When the winter came around we turned off the heat upstairs since nobody stays up there for now and the downstairs one worked fine. This loop has a Nov 16, 2019 · Gas and Oil Home Heating Furnaces - Heating Upstairs but not Downstairs - Since I’ve needed to turn my heater on with the temperature drop I have been having issues. htmlSolving A Baseboard Heat Problem----- Jan 28, 2022 · Baseboard Heat: Hot water baseboard heat repair tips & troubleshooting FAQs: Here we give simple steps to get that cold or not warm-enough hot water heating baseboard back to snuggly warm again. Knock on it. My main level is not heating up, but the upstairs is working just fine. Temperatures are lowering and last night we decided to turn on the heat. Check the Thermostat Settings. The heat comes on upstairs when I turn it on from the upstairs thermostat. This past week, my mother came to town so we turned the upstairs one on auto to 70 deg to match downstairs. Customer: Our upstairs baseboard hot water heat isn't working. 36 its still almost 1. I was monkeying around with stuff under the house, which perfectly coincided with the faulty baseboard heaters. Air Trapped in the System. I had a similar problem and after resolving the situation it inspired me to actually replace my baseboard heaters with Pensotti Steel Panel Radiators, at least in my downstairs. Hot water heats up in a boiler, travels through insulated pipes, and enters baseboard units. Shortly afterwards, my wife noticed that in the morning, we didn't have heat upstairs. How long have you been dealing with this? Baseboard heat doesn't work upstairs. After Oct 22, 2023 · If you’re short on time, here’s a quick answer to your question: The most likely causes of a baseboard heater not working in only one room are a closed valve or thermostat problem for that room, an airflow blockage, or a leak in the heating loop for that room. Following those basic checkpoints we report on frequently-asked COLD HEATING BASEBOARD QUESTIONS AND ANSWERS THAT CAN HELP DIAGNOSE and fix baseboard Cold Heating Baseboard Diagnostic Guide: how to diagnose a heating baseboard section, loop, zone, or room that is not receiving heat. Dec 12, 2024 · What are common reasons for hot water baseboard heaters not turning on? Hot water baseboard heaters may not turn on due to thermostat settings being incorrect, a power supply issue, or low water levels in the boiler system. Aug 18, 2023 · If your baseboard heater is not necessarily broken, consider bleeding your unit to help it run more efficiently. Not sure if call to heat for each zone valve works. On the top floor, one zone controls all the baseboard heaters on that floor. Our house is 1300 sq ft downstairs (zone 1) and about 1100 sq ft up (zone 2). I go to the problem baseboard and open the air bleeder valve and only water comes out in a steady stream. Nov 8, 2017 · I have a wood stove as a secondary heat source. There are 3 lines going upstairs: 2 are hot and 1 not getting hot. - Good Evening All! I am generally new to heating so I am learning about this stuff as I go, and trying my best! So, quickly, I have a gas slant fin furnace. An anti-scald device that’s stuck or a pressure-balancing valve that’s malfunctioning can reduce the hot water reaching your upstairs fixtures. the thumbs up and say they believe the line has air in it and is not flowing. I have a two story farm house that has a single continuous line of baseboard heat. Later we switched the AC to a heat pump, so now we only need our baseboard heat for short periods of time in specific rooms on cold days. Burners burn, thermostat is on the first floor and triggers them when is necessary. I have a 2 story home and cannot get heat to the 2nd story anymore. I have a gas furnace With a hot water baseboard system. However, the heat was minimal upstairs (most of the heat was in the back rooms on the same side that my father installed the valve for bleeding, on the front side of the house you could hear water circulating slightly, but apparently it wasn't hot water by the Jul 25, 2014 · This current setup means that I have to have my dining room heater on in order to heat an upstairs bedroom or bathroom. Upstairs remains fine. The pipes to the upstairs is hot but not the pipe after the split that goes to the main level. Verify that the thermostat is set to a temperature higher than the current room temperature. I cannot see how this is acceptable. Furnace, thermostat and pump is working. Not really enough info given. Baseboard heat is connected to a boiler. Sep 2, 2021 · You could crank up the heat to warm the second story. One thermostat in living room. Feb 20, 2022 · Baseboard heaters are a great convenience, which is why many builder owners choose them for their homes. Dec 31, 2024 · Is your baseboard water heater failing to keep your home warm? This article explores common issues like thermostat malfunctions, trapped air, and water leaks that can impede heating efficiency. Basics of the system: We have a boiler which circulates hot water thru baseboard copper pipes to provide heat to the house. Baseboard heaters are suitable for when you have one, maybe two rooms that are too cold upstairs. Replace old batteries in battery-operated thermostats. Common Electric Baseboard Heater Issues Electric baseboard heaters, while generally reliable, may face issues that impact their performance. No forced hot water heat in upstairs zone; Author: Chuck Bradley (MA) I have forced hot water heat from Beckett burner and Peerless boiler for a two floor house with two zones, one for each floor. If so, then it could be a short in the system. Blocked Heat. FWIW - I can’t turn the square thing on the 2nd floor heater for the life of me. We keep all the upstairs rooms closed (never use) and the thermostat is in the upstairs hall. thought I had all air out. Some of the baseboard are warm at best, and some are stone cold. 2 zone system. improve insulation. I started looking at the downstairs thermostat to check for any obvious issues, loose wires etc. I am so confused This video will show you how to bleed trapped air from a baseboard heater. Room reaches 70F: thermostat turns off (I can hear the click), one of the heaters cools to around 110F while the other cools to around 160F. Tried each separately. Baseboard Heater is Not Working in One Room. The thermostats are both set to 80 degrees Farenheit and the temperature of the house is about 58 degrees upstairs (main level) and 65 downstairs (basement). Feb 9, 2023 · In this article, we will delve into the potential causes of baseboard heat not working upstairs and provide some troubleshooting steps to help you fix the issue. We have 2 thermostats, 1 up, 1 down. why. I do not reside at the home at issue. Jan 28, 2022 · I have two zones in my house, upstairs & downstairs. Plumber drained, fixed pipe, and then turned back the valves. My gas heat is Burnham heater. Heating System: Gas fired, two zone, hot water baseboard heating. Is there any phenomenon causing heat to stack up and leave the first floor struggling? Actually, there are still two rads on the 3rd floor that have still not been installed yet, no paint on the wall, I guess. Apr 2, 2021 · In the mean time, the only way for me to get heat to the zones upstairs is to do the following: 1. Please feel free to ask any questions. Carson Dunlop Associates' sketch (below left) and our photo of a heating baseboard (below-right) show a typical modern hot water heating baseboard system installation. I've bled the upstairs line many times, even using the "pressure bell?" to increase the pressure to about 25 and blast it out repeatedly. Since this has happened, the downstairs will not heat. 1 2. The 1st floor zone is working fine. Its a solenoid so carefully touch both sides coming out of it ( while there is a call for heat in that zone) if one sides hot and the other not then thats your problem. The word Upstairs the pipes are cold. Dust, debris, and other items crowding the heater can be a fire hazard and reduce the heater’s efficiency. I have only opened up and tested one of the baseboards. The night it stopped working, the temperature outside was below freezing. Gas fired-forced hot water (not baseboards but air handlers-one in basement and one of 2nd floor) 3 circ pumps-and a taco controller. 3. They are highly energy-efficient and give you control over the temperature of each room of your house. House style and Dec 30, 2016 · I would start to get heat out of the first baseboard in the loop, but no further, then eventually the heat would fade. She says the propane is not a permanent heat source. Also it is not recommended to have baseboard heat even on its own thermostat and zone when you have other zones with cast iron. But since you have baseboard heat and the problem is in your downstairs, but not your upstairs an airlock is less likely. Not only are you paying a lot of money to correct the problem. the finned tubing of baseboard heaters that use that component (photo at above-left) or check for air flow blockage at the bottom opening (cool air inflow) and top opening (warm air outflow) at the baseboards if the actual baseboard piping gets hot but not enough heat comes into the room. I first suspected there was air in the system that the pump couldn't circulate through. We have replaced a couple of stats. When i bleed the one bleed valve on it, water immediately comes out. So, I bled the system zone by zone. Base board transfers heat much faster therefore will sit cold while cast iron rads are hot for much longer time heating a room. Boiler in basement with loop around the basement ceiling perimeter, with a set of venturis and Tees going to each baseboard upstairs and even to the 2nd floor. Dec 20, 2019 · I have hydronic heat system at home. My system says heating is on upstairs but no heat to any of the radiators apart from the landing one. I'm opening the walls upstairs now and was trying to see if there was a way to run ducts up thru the main floor bathroom to the 2 upstairs bedrooms, but I'd still need to run one up to the other upstairs bedroom. I do not have any purge spigots, just shutoffs before the recirc pumps. So, you’ll probably have to replace your current heater, too. Hi everyone. Dec 6, 2019 · 2 zone (1 radiant floor, 1 baseboards) hot water heating system. I live in Wisconsin - so it’s not an ideal time to do this, but it’s also causing one side of our home to be noticeably cooler. Set the thermostat to 70F: heaters warm to around 200-250F. They are all a little different some use a special key, screwdriver, or have a t-bar, etc. This process involves locating the high limit switch and following specific steps to reset the heater. For this step you need to be sure that there is water everywhere in the accept that heat rises and basement will always be colder no matter what you do. Convection has to do with the movement of molecules under different temperatures and the transfer of heat, but all you really have to remember is that it makes hot air rise up and cold air fall towards the floor. One baseboard won't heat up. For all that, you only get two zones: Upstairs and downstairs. I turned the heat on Do you think we should still get the wall furnace ? Ideally, we would like to install baseboard heating upstairs, just like the main floor with separate control panel, but not sure how that would work or be worth it. Radiant floor (t’d off main feed) seems to be working fine. If its not that my second guess would be a zone valve. It’s a significant investment for just a bit more customization. Baseboard Heaters. At 44% efficient at -22f, with a COP of 3. When I turn the thermostat on and off, I can hear things click in the basement, what it is I don't know. I don’t have any valves to open on the radiators if air could be causing the problem. But, heat to the first floor is fine (it was actually warmer than usual on the first floor baseboards). But, that overheats the first floor. The upstairs outgoing pipe before and after the zone valve is too hot to hold. The system has four zones and the upstairs is the only one not working. Baseboard heaters work using a scientific principle called convection. Keep reading our baseboard heater troubleshooting guide to fix your issue Ok New Years Eve, my baseboard heating stopped working on the second floor of my house. Jan 23, 2007 · Boilers - Home Heating Steam and Hot Water Systems - basebord heat not circulating hot water - hi all, our house has a oil fired burner/furnace. Ensure it’s on heating mode. One zone. I noticed that regardless of the thermostat reading (nonprogrammable circle honeywell heat only) i can feel significant heat coming off the baseboard heaters. I turn on the thermostat and let it go for 20 minutes. Nov 7, 2012 · It's a 1962 home with hard water. The heat transfer from baseboard <> air is a much lower temperature gradient and can limit throughput. Contractor's Assistant: I'll do all I can to help. Last night for example I had my upstairs thermostat set on 65 degrees and it was 77 in there. Once you’ve ruled this out, check to see if the circuit breaker is hot. Dec 7, 2010 · Hi, Glad I found this forum. If your baseboard heat is cold with the heat turned on, this might work for you. Is this typical? Dec 2, 2024 · I'm in a house that has steam heat (or it at least has a boiler and some kind of water-based heating) and the very small profile baseboard radiators along the walls. com/baseboard-radiators-not-heating-room-up. Thanks. danpik · Registered. A faulty thermostat may record inappropriate temperature readings and switch off the baseboard heater before reaching the set temperature. Jan 10, 2010 · The home is a slab built (no basement) with a 4 ft crawl space underneath. Jul 30, 2021 · Unlike purely radiant heating, electric baseboard heating warms the air and not just the objects in its path, and unlike space or wall heaters, a baseboard unit doesn't need a fan. Turn the dial all the way down to "off": heaters stay the same temperature. It'd be nice if we could have the upstairs get a little warmer without making the downstairs uncomfortably warm, but oh well. How Gas Baseboard Heaters Work . I believe there are two zones (two thermastats), Mar 30, 2009 · Boilers - Home Heating Steam and Hot Water Systems - Heat not hot upstairs - I will do my best to answer all the questions, please excuse me if i dont i am a first time home buyer and still learning a lot of this stuff. If it's an air plug, might it work itself out over time-there is some knocking when the water starts Dec 23, 2015 · The house has hydronic baseboard heating and a very old gas boiler. So, you can consider your budget and which rooms need what kind of treatment. com/stores/steve-lavhttps://www. com/stevenlavimonierelavimoniere productions llcsubsc Sep 28, 2024 · A: If the heater doesn‘t respond to thermostat adjustments, it may be faulty. Perhaps someone can assist me. It started by only heating the front rooms of the house upstairs and now it is heating none of them. We recently had a leak in one of the lines down In the basement repaired so I’m wondering if air got into the system and needs to be bled out. Now that I've done all the testing, and reassembled the heater, still no Boiler Not Keeping House Warm Hello everyone, In April of last year we got a new hot water boiler and baseboard radiators installed in the house. As I walk past one thermostat I notice the temperature is colder than the set point. turned the unit off to give the boiler a chance to rest, turned it back on, and really, very little water flowing through downstairs run. Careful water may be hot if boiler has been running. I just bought a townhome in Victoria, BC. He replaced the bare copper pipe with the heaters (finned copper pipes). zjsnfe haivc wlni qoes dmtz aod hyulzg rkdbwtqf amdzc sud